TOWER COMPLETION INSPECTION
TOWER
Verify Tower is Plumb
Check for Bent or missing
members
Verify tight lace bolts
Verify tight flange bolts
Verify Sector mounts tight
and level
Verify Stiff arms installed
at correct angle
Verify Wave guide attachment
Verify Safety climb
attachment
Antennas
Brackets tight
Verify Correct
azimuth and downtilt
Verify Weather proofing
Verify Jumper attachment
Verify Jumper bending radius
meets mfg. specifications
Verify Color coding
Verify Correct down tilts
REMOTE RADIO HEADS
Verify Brackets tight
Verify Weather proofing
Verify Grounding
Verify Access door secure
CABLING
Verify Fiber attachment
Verify Cable attachment
Verify Cable bending radius
meets mfg. specifications
Verify Grounding
Verify Color coding
Verify Entry boot into
building
Verify Power cable attachment
ICE BRIDGE
Verify properly attached to
concrete
Verify Per specifications and
level
Verify Trapeze equally spaced
and level